Contents
  1. Go to CGTech Help Library. Installing CGTech Products
  2. Vericut tutorial pdf | MyFolio
  3. Learn to Programme
  4. Machine builder / simulation

sions and notes to a VERICUT im- age that can then be added to a. VERICUT report. All VERICUT re- ports can be saved in standard HTML or PDF formats. This page contains a variety of marketing literature in PDF format and many video animations demonstrating the capabilities of VERICUT. Note 1: If you are. The following section contains a variety of marketing literature in PDF format and many videos demonstrating the capabilities of VERICUT. Note: If you are.

Author:BERNEICE MISENHIMER
Language:English, Spanish, Dutch
Country:Bolivia
Genre:Biography
Pages:661
Published (Last):05.09.2016
ISBN:590-8-19392-650-2
Distribution:Free* [*Registration needed]
Uploaded by: ROWENA

51661 downloads 131003 Views 35.66MB PDF Size Report


Vericut Tutorial Pdf

requirements of machining a real part, VERICUT needs the NC program data, a description of PDF — Use this option to create a report in PDF format. (PDF. The sessions, currently being made available at no cost to current customers, have been designed to teach, quickly, a new VERICUT user the fundamentals of . VERICUT Training Sessions - Ebook download as PDF File .pdf), Text File .txt) or read book online. This session 4 & 5 Axis Mill Training Tutorials. Uploaded.

Ruby's presentation at COE. The thing that was messing me up for so long is the trunion on this machine. It starts out with the table XY parallel to the Z axis and machine sim didn't like that. If anyone has suggestions about dealing with that, please share. I still have a long way to go, but this is the right way.

The control can then miraculously fit in the circular move. Sometimes on training course my students have read stuff on the internet about I J and K. My stock answer is unless your working on a really old machine and I mean dog shit old you wont need it. Toward the end of the programming course I admit to lying and drop the bombshell that maybe you do need to know just a little bit about I J and K.

Anyway you can actually live your whole life and never worry your pretty little head with such crap as I J and K. What about a full circle your smart arsed friend will ask.

Go to CGTech Help Library. Installing CGTech Products

Easy you program it in two halves. Actually I think it is a bit of a cop out because there is a very easy way. By the way in England if your mate is pissed it means he is intoxicated. In America I believe it means he is unhappy.

Anyway piss can be used in many contexts. Piss easy means easy like taking a piss urinating for the posh engineers Anyway this program is a macro you can use to easily program a circle of any size in cutter compensation. In the above main program the tool radius is stated as D17 and 1 is the required radius.

Insert the CD and run the Windows installation program. If your computer does not automatically start the installation program, double-click on or run the "install. Follow the installation "Wizard". The last choice, prior to the "Finish" screen, begins the installation.

Vericut tutorial pdf | MyFolio

Overview of the installation steps: Choose the installation language. Accept the License Agreement. Choose the type of installation. Choose Windows 32 bit or Windows 64 bit, depending on your operating system.

Learn to Programme

Select desktop icons and start menu buttons to add to the installing user's profile. Enter the license server host name. Special Information for Redundant License Server configurations A redundant license server configuration uses three 3 license server computers.

One of the license server computers is designated the "leader", the other two are "followers". The redundant license servers are configured in the next step. However, during installation you must enter the license server host name. If you are using redundant license servers you must enter all three host names in the installation screen's text field, in the following format: hostname1:hostname2:hostname3 Where "hostname1" is the actual host name of the leader or main redundant server, and "hostname2" and "hostname3" are the names of the follower servers.

CGTech recommends that you install software as the 'root' user, but it is not required. Do not 'set user' su to root as this does not always correctly execute the root account's login process. Carefully read and follow the information in the "Next installation task" link at the bottom of this page regarding configuring and starting the license server. If yours does not, or if it mounts the CD without read and execute permissions, dismount and remount the CD.

UX" without the quotes.

Machine builder / simulation

If this command fails, try: ". Follow the on-screen instructions. The redundant license servers will be configured in the next step.

If you are using redundant license servers you must enter all three host names in the installation screen's text field, in the following format: hostname1:hostname2:hostname3 Where "hostname1" is the actual host name of the leader redundant server, and "hostname2" and "hostname3" are the names of the follower servers. Typically this is done using your UNIX 17 19 platform's system administration utility. However this can also be configured manually by either adding the 'commands' directory to the PATH environment variable for each user's login process, or by copying the files to a directory that is already in each user's execution path.

NOTES: 1. Licensing from earlier major versions will not allow newer versions to run. Point releases, such as 6. If you have not requested a license from CGTech, go back to the Introduction for information about how to request a license. The license contains instructions on how to create a license file.

Those instructions are repeated here as well. The Sentinel RMS license server is a full featured software licensing tool used by several software companies to license their application programs. Sentinel RMS contains optional features not mentioned in this brief discussion of basic license server configuration. Be sure to stop the current license server and remove its service, if applicable. Redundant license servers If you are using a special redundant license server configuration, go to the Windows Redundant License Server Setup section.

Configure the license server to automatically start as a Windows service recommended NOTE: The following steps must be done by an Administrator user. In the command prompt window read the informational messages then press any key to continue. If you use another program or cannot access the license from the license server computer, save the license as a "Text Only" or plain text file, then drag and drop the saved file into the Create VERICUT License File screen.

Continue reading messages displayed in the command prompt screen, press any key to continue. When the command prompt window closes, the license server should be configured for use and you can proceed to the next step. You can confirm that the server program is running using the Sentinel License Administrator program. You should see your license server computer's host name appear under the Defined Servers list under the "tree" displayed on the left side of the window.

NOTE: If for some reason you cannot configure the license server service to start automatically as described above, and then see Starting a Temporary License Server. The Sentinel RMS license server is a full-featured software licensing tool used by several software companies to license their application programs.

Sentinel RMS contains optional features not mentioned in this brief discussion of a basic license server configuration. Configure and start the License Server.

Related Post: EDGECAM TUTORIAL PDF

CGTech recommends you configure the license server program to automatically start when you start your license server computer. The method for doing this depends on your particular UNIX platform and how your system's administrator prefers to manage the computer's startup process.

If you have automated the license server startup, remove it from your system's startup configuration using your systems' management utility program. Add this script to the license server computer's startup processes using your platform's system management utility. If your platform's system management utility gives you a choice, add the license server startup after the network services startup. Reboot the computer after adding the license server program to your system's startup process to verify that it starts correctly upon reboot.

If it is not possible to reboot your license server computer now, start the license server program manually using your platform's system management utility.

However, the server process will be owned by the 'root' user and will terminate when the 'root' user logs-out. Manually starting the license server program in this way is not recommended as a permanent configuration. Verify the license server started. The license server program should now be running on your computer and should be configured to automatically start.

A utility is provided to detect the license server 23 25 program. Execute the lswhere program from a command or terminal shell to determine if the license server program is running. Server Address : Server Name : mycomputer in this example the server computer's host name is 'mycomputer' and its IP address is 3. Copy the license keys from the CGTech license to a text file. Open the license you received from CGTech. Copy the license keys from the license. DO NOT copy the entire text.

Start with the line that begins ' Company: ', and select all lines down to and including the line ' End of license '. Paste the lines into a plain text editor such as vi. Do not use a word processing-type editor like Microsoft Word. Save the text as a plain text file. Name the file and save it in a directory so that you can easily find it later. This file is not used once the license keys are added to the license server in the next step. CGTech recommends you keep the file for archive purposes.

NOTE: When pasting into the plain text editor make sure that the long license key lines are not automatically truncated or split into separate lines.

Add the license keys to the license server and license file using lslic. Add the license keys to the running license server and save them in the license file. The license keys are loaded from the file saved in step 3D above. The F option adds the keys to the license server from the specified file, and saves them in 'cgtech.

Similar posts:


Copyright © 2019 maltmagecapski.tk. All rights reserved.